A 7-byte PDO mapping and an 8-byte host buffer.
Use entry-level offsets to decide what to investigate next, rather than treating a length mismatch as a confirmed fault.
November 20, 2026 · PcPart24 engineering notes
Illustrative example. The configuration and observations below are invented teaching inputs. This is not a customer project, hardware test or claim of a resolved fault.
1. Define the direction and the entries
Here, RxPDO means data received by the slave: master outputs. TxPDO means data transmitted by the slave: master inputs. Each direction has its own starting offset. The labels are generic and do not imply a particular device profile or supported object dictionary.
Assume the slave's active RxPDO mapping contains the entries below, including an explicit seven-bit padding entry. This example assumes consecutive bit packing; a real device's supported mapping and alignment rules must be checked.
| Entry | Bits | Start byte | Start bit |
|---|---|---|---|
| Control word | 16 | 0 | 0 |
| Target value | 32 | 2 | 0 |
| Enable flag | 1 | 6 | 0 |
| Explicit padding | 7 | 6 | 1 |
The total is 16 + 32 + 1 + 7 = 56 bits = 7 bytes. The last byte contains the enable bit and seven padding bits. An offset of byte 6, bit 1 is not a decimal value of 6.1 bytes.
For a separate illustrative TxPDO, a 16-bit status word, a 32-bit actual value and eight status bits also total 56 bits. Its offsets begin at byte 0 independently; do not concatenate both directions unless your master API explicitly describes a combined image.
2. Reproduce the arithmetic
Paste the following into the RxPDO side of the free calculator. The mapping text stays in your browser.
Control word,16 Target value,32 Enable flag,1 Explicit padding,7
Download the illustrative offset table as CSV. The CSV describes this teaching layout, not your actual slave's mapping.
3. Compare a like-for-like length
Suppose the application reports an eight-byte output buffer. Before changing it, identify what that number means: allocated memory, serialized process data, a master API region, or a Sync Manager length. An eight-byte allocation can legitimately contain seven bytes of process data. A compiler's structure layout may also add padding, but its layout depends on the ABI and declarations.
Ask which exact bytes the application writes and the master transmits. Compare the active assignment and mapping, generated master configuration, Sync Manager size and per-field application offsets. Neither a seven-byte calculator result nor an eight-byte host buffer proves the cause of SAFE-OP.
4. An illustrative configuration review report
This compact sample shows the structure of a written finding. An actual review is limited to the evidence supplied and the agreed question.
Question and supplied inputs
Question: Could the reported output-length discrepancy explain the failed transition?
Teaching inputs: the four-entry mapping table above, a statement that an eight-byte host buffer is allocated, and a reported failure to reach OP. No actual device logs, ESI, ENI, capture or AL status are supplied in this example.
Observation versus hypothesis
- Arithmetic finding: the stated mapping totals seven bytes. This follows from the supplied entry widths.
- Unresolved discrepancy: the eight-byte host allocation has not been reconciled with the number of bytes transmitted.
- Hypothesis: an incorrect transmitted length or field layout could be relevant. Memory allocation size alone does not demonstrate either error.
- Not established: the root cause, expected WKC, correctness of active assignments, or synchronization performance.
Prioritized next tests
- Preserve the first failing state transition and exact AL status. Record master and device versions and the configuration revision.
- Read the supported active mapping and assignment information. Reconcile entry widths with the configured Sync Manager length using vendor documentation.
- Inspect the master API's actual process-data length and the application's serialized field offsets. Distinguish buffer capacity from bytes used.
- In a safe test setup, use recognizable patterns and check individual fields and byte order. Do not test an actuator with uncontrolled outputs.
- If a mismatch is confirmed, change one configuration element, repeat the same test, and record AL status, relevant datagrams and expected/actual WKC.
Acceptance evidence and remaining limits
The comparison should produce an entry-to-offset table and a record of the configured and transmitted lengths. Any claim of successful operation requires target observations and the agreed acceptance test. Correct bit arithmetic does not establish valid watchdog settings, DC timing or production readiness.
5. Prepare your own evidence
Use the evidence worksheet to record what is known and leave unknown values explicit. Keep original files and identify which logs came from the same failure. Agree authorization and a transfer method before sharing proprietary material.
For the surrounding configuration checks, see the ESI / PDO mapping checklist and SAFE-OP / WKC investigation checklist. Device-specific behavior must follow the vendor's documentation; the EtherCAT Technology Group technology overview provides general protocol context.
Need a review of your configuration?
The $149 USD pilot covers one focused question, up to 90 minutes of offline review and one written clarification round. We confirm evidence, scope and schedule before payment.
Read the full review scope · All free resources